N39200 Series Mbiri-Gadziriso Inogadziridzwa DC Simba Magetsi
N39200 series is a high-accuracy & dual-channel programmable DC power supply, available for benchtop use. N39200 standalone supports 2 channels output, with each channel isolated. Both local operation on front panel and remote control on a computer are supported. N39200 can be widely used in lab test, system integration test, production aging line, etc.
Zvinhu Zvikuru
● Voltage range: 60V / 150V
● Tsanangudzo yepamusoro yekubata sikirini
● Nzvimbo yemazuva ano: 4A/8A/10A/20A
● Mushandisi-ushamwari interface
● Simba remhando: 200W / 400W / 600W
● LAN port uye RS232 interface
●CC&CV basa rekutanga
● Dziviriro dzakawanda: OVP, OCP, OTP uye pfupi pfupi
● Dual LAN ports design
● Chishandiso chimwechete chine 2 chiteshi, chiteshi chega chega
Mazano Okushanda
● Rabhoritari yechikoro
● Rabhoritari yeR&D
● Kuongororwa kwemutsara wekugadzira
● Muedzo wekuchengetedza
Mabasa & Kubatsira
Dual chiteshi, compact size uye huremu huremu
N39200
series adopts 2U and half 19 inch design, with 2 channels in a single
device. Each channel is isolated. One device can support 2-station test
simultaneously, which simplifies the test platform and improves test
efficiency
UI flat icons
UI flat icons inopa nyore uye nekukurumidza kushanda.
Virtual keypad
N39200 yakagadzirwa iine chaiyo kiyipad yekuisa paramita.
SEQ modhi
SEQ modhi inobvumira kusetwa kwekubuda kwemagetsi, kuburitsa ikozvino uye kugara nguva yenhanho imwe chete.
Cascade mode yekuwedzera simba
N39200
supports two channels parallel mode internally. Under parallel mode,
the output voltage remains the same. The output current and power will
be doubled.
CC & CV yekutanga basa
N39200
has the function of selecting priority of voltage-control loop or
current-control loop, which enables N39200 to adopt the optimal test
mode for different DUTs, and thus protect the DUT.
As
shown in figure one, when the DUT requires reducing voltage overshoot
during test, such as supplying power to a low-voltage processor or FPGA
core, voltage priority mode should be selected to obtain fast and smooth
rise voltage.
As shown in figure two, when the DUT requires reducing current overshoot during test, or when the DUT is with low impedance, such as battery charging scenario, current priority mode should be selected to obtain fast and smooth rise current.
Dual LAN ports yeakawanda maturusi ekudzora
N39200 yakashongedzerwa nembiri LAN ports, iyo inogona kutsigira akawanda maturusi kudzora kwekukurumidza kugadzirisa uye bvunzo.